$7,819.00/Each

Accessories & Options

Earn up to $234.57 back (23,457 points)with a Webstaurant Rewards Visa® Credit Card

Other Available Sizes:

Usually Ships in 5-7 Business Days from manufacturer

Lead times vary based on manufacturer stock

Product Overview

  • Type 1 hood for grease-producing equipment; PSP makeup air system
  • Includes sloped-front hood canopy, exhaust fan, and supply fan for makeup air
  • 18-gauge 430 stainless steel construction on all exposed surfaces
  • For ceilings under 10'
  • 115/230V belt-driven exhaust fan (2750 CFM), 115/230V untempered supply fan (2200 CFM)
UPC Code:400013628435

Specs

Quantity
1/Each
Shipping Weight
662 lb.
Length
11 Feet
Depth
48 Inches
Ceiling Height
Under 10'
Amps
6.5 - 13 Amps
Phase
1 Phase
Voltage
115/230 Volts
Wattage
1,495 Watts
Features
Made in America
Fire Suppression
Optional Fire Suppression
Horsepower
1 HP
Plug Type
Hardwire
Style
PSP Makeup Air Hood Systems
Type
Type 1

Customer questions about this product

Does my hood package include a control panel for operating the fans and lights?

Hood packages do not include control panels with the package. A control panel is often provided by the installer, or it can be purchased separately.

How do I choose the right hood for my application and local codes?

Each local jurisdiction has different rules and regulations regarding exhaust hoods. We recommend you contact your local authority to obtain the specific requirements and regulations for your intended application in your respective jurisdiction before placing your order; typically the approval authority will be the building, fire, or health department. We may also reach out to gather additional information about the layout of your application to help ensure that this hood will meet your needs and suggest modifications so that you are getting the best performance possible for your specific layout. For further assistance in selecting the right hood for your application, please contact our Customer Solutions team.

How do I know what size hood I need?

To be compliant with NFPA and International Mechanical Code, canopy hoods must be sized to have a minimum 6” (152mm) overhang beyond the top horizontal edge of the surface of the cooking appliance on all sides. To size your hood accordingly, measure the horizontal distance (width) of the cooking surface, add 12" to cover the 6" for each side, and round up to the nearest foot. Example: You have a 36” flat top griddle, 24” charbroiler, 24” range, and a 16” deep fryer. This setup has a total width of 100", plus 12" for overhang, which is 112" or 9 feet 4". Round this up to a 10' hood.

I am interested in an “island” type hood in the middle of the kitchen. Where can I order this type of Hood?

Island hoods require a quote from our special orders team. Please email Customer Solutions with any questions.

I am interested in ordering fire suppression with my hood, what is involved in that process?

Fire suppression systems are frequently required by code for type 1 hoods, and need to be designed to fit the specific layout of your cooking line.

Kidde Systems use APC (Aqueous Potassium Carbonate) wet chemical fire suppression. The tank is typically exposed unless a cabinet is requested. They come pre-filled.

Ansul Systems use Ansulex wet chemical fire suppression. The tank is typically installed in a wall-mounted cabinet. They must be filled and charged.

Both systems meet UL300 standards, and will require a certified fire safety installer to hook up, test, and pass inspection.

Follow these simple steps to add a system to your hood!

1.) Choose whether you would like an Ansul Deluxe or Kidde fire suppression system for your hood, under the "Fire Suppression" dropdown. The Ansul Deluxe system includes the gas shut-off valve, enclosure, chemical, and nitrogen cartridge.

2.) A member of our team will reach out to gather more information about your application so that the fire suppression system can be configured correctly. The sooner you provide answers to these questions, the sooner we can proceed with your order!

3.) If our team has any additional questions or concerns based on the information provided, we will work with you to resolve them and find the correct fire suppression solution for your business.

Is anything else needed to process my hood order?

Yes! In the Resources & Downloads section we list 2 forms – Receiving Agreement & Order Acknowledgement. These forms are required by the manufacturer to begin processing your order. We encourage you to promptly complete these forms after your order has been placed and email them directly to [email protected] with your order number in the subject line. If you selected Fire Suppression as part of your hood package, please also complete and submit the Fire Suppression Layout form located in the Resources & Downloads section. A member of our team will also contact you after the hood is ordered to ensure completion of the forms and processing of the order.

My wall / ceiling is made from combustible materials. Will that pose a problem?

Many common building materials are considered non-combustible such as stone, brick, plaster, steel, concrete, and glass; however, if your walls, studs, joists, or ceiling are made of combustible materials such as light-weight wood framing or heavy timber, special accommodations must be made if the hood will be mounted within 18 inches of the combustible material. Some materials, such as drywall or drop tile, may vary based upon local codes. We recommend you consult your Authority Having Jurisdiction (AHJ) if there are any specific questions regarding what is considered a combustible material. We will work with you to determine if adjustments are necessary using the information you provide in the dropdowns and after your order is placed.

Will the layout of my facility affect the fan specifications?

The CFM ratings given in the description are what your hood will most likely be designed to perform at - however, factors like long duct runs, multiple duct turns, and high heat equipment like fryers and charbroilers may necessitate a more powerful fan with a different drive type or different specifications, and we will work with you to determine whether any modifications are needed after your order is placed. The fan specifications given in the description are reflective of most installations.

When I order this product, can I request liftgate delivery?

This item is too large and heavy for a liftgate. It can be delivered with a truck-level loading dock or forklift. Contact our Customer Solutions team prior to placing your order if you would like to discuss other delivery options.

Ask your own question!

Details

Keep your kitchen free of hazardous grease buildup with this Halifax LPSHP1148 11' x 48" type 1 commercial kitchen hood system. This unit is suitable for use over any equipment that has a surface operating temperature under 700 degrees Fahrenheit, and that is required by fire code to have a type 1 hood - this includes fryers, griddles, charbroilers, conveyor pizza ovens, or any equipment that produces grease during the cooking process. The hood removes the grease-laden vapors produced by your equipment and prevents them from accumulating in places where they could become a fire or sanitation hazard, leaving your kitchen clean and safe to use!

It uses a PSP (perforated supply plenum) makeup air system, which introduces supply air into the room through the front of the hood. Makeup air is important in applications where the kitchen doesn't have enough fresh air coming in to replace the air exhausted by the hood, since your hood requires this replacement air to perform to specifications and remove grease, smoke, and VOCs effectively. It contains a 115/230V belt-drive exhaust fan designed for 2750 CFM, a 115/230V untempered supply fan designed for 2200 CFM, and your choice of a wall, flat roof, or pitched roof curb mount for each fan.

The hood uses (5) 20" x 20" and (2) 20" x 16" baffle-type filters, and the filters are made from stainless steel to provide durability and make cleaning easy. Grease extracted by the filter is collected in a grease trough, which drains into a stainless steel grease cup for disposal. 18-gauge 430 stainless steel is used on all exposed surfaces to give it excellent durability and cleanability, while the MIG-welded frame provides seamless, liquid-tight joints. The hood features a sloped-front canopy design that is great for low ceilings, providing extra front clearance and comfort for chefs, and dropping down close to the equipment in the back. This model is also engineered with a 3" air gap on the back of the hood, which provides clearance and protection for combustible walls where code requires.

4 pre-wired lights illuminate the equipment under your hood so that you can easily see what you're doing while cooking, and they require a 115V electrical connection to the junction box. This hood should be used in applications where the ceiling is under 10' tall. 6 hanger brackets are included to make installation easy. It must be hard-wired, cords and plugs are not included.

Overall Dimensions:
Length: 11'
Depth: 48"
Height (Front): 12"
Height (Back): 24"

This Item Ships via Common Carrier. For more information and tips to help your delivery go smoothly, click here.

Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. If you need your items by a certain date, please contact us prior to placing your order. Expedited shipping availability may vary. We cannot guarantee that this item can be cancelled off of the order or returned once it is placed.

Attention CA Residents:

  • Made in America

    Made in America

    This item was made in the United States of America.

  • Hardwired

    Hardwired

    This product must be hardwired by a professional; it does not plug into a standard wall outlet.

  • UL Listed, US

    UL Listed, US

    This product has been certified by the Underwriters Laboratories (UL) to meet applicable safety standards required for use in the United States.

  • UL Classified EPH

    UL Classified EPH

    This product has been certified by the Underwriters Laboratories (UL) to meet applicable ANSI/NSF standards and / or other food equipment hygiene codes and requirements.

Need Parts & Accessories?

Shop replacements and accessories for this item today!

Resources and Downloads

A PDF viewer is required to view this product's information. Download Adobe Acrobat software