Can this unit be built into cabinetry?
It should not be built into cabinetry. This unit requires 3” of clearance on all sides for proper ventilation.
Does adding optional accessories impact the lead time on this product?
Yes. If optional accessories are added to this product, this product may require additional lead time.
Does Avantco warrant this item for use in a food truck?
Avantco warrants new equipment sold to food truck customers to be operational for a period of 30 days from the date of delivery if installed and maintained correctly.
Does this item ship to Canada?
This product cannot be shipped to Canada.
How do I correctly install the shelves into this unit?
To promote proper air flow through your Avantco unit, please ensure that the wire ledges on the shelves are positioned toward the back of the unit. These ledges help keep enough space between your product and the back wall so that cold air can adequately circulate through the cabinet. Incorrectly installing the shelf ledges can restrict airflow, causing the temperature in the bottom of your unit to rise.
How do I know if this unit will fit under or match the height of my ADA-height counter?
Many manufacturers offer their refrigeration equipment in several different height options to best meet your needs. Here's a breakdown of how we classify these different heights:
Counter Height: Work surface is more than 34" high; standard-height unit.
ADA Height: Work surface height is 34" or less; complies with ADA regulations.
Low Profile: Work surface height is less than 32"; designed to fit under most ADA-height counters.
If the unit you are purchasing does not have a flat top, such as a worktop or sandwich/salad prep table, it may affect whether or not it will align with certain countertops. To ensure that the product will meet your needs, please reference the product's literature and specifications.
I haven’t heard of R-290, R-600a, R-513a, or R-448A refrigerant before. What is it?
R-290 (also known as high purity propane or CARE 40) and R-600a (also known as refrigerant grade Isobutane or CARE 10) are hydrocarbon refrigerants. R513a (also known as Opteon XP10) and R-448A (also known as Solstice N40) are HFO (hydrofluoroolefin) refrigerants. They are being used by some manufacturers in response to the EPA’s Significant New Alternatives Policy (SNAP) Program.
My unit was delivered, but I don’t see any casters?
The units come with casters preassembled underneath the pallet.
Why is there a step in the interior of this undercounter unit?
This unit’s refrigeration system is located in the lower rear of the cabinet, causing the step in its interior. The step may decrease the inner depth of the cabinet's lower interior versus what is listed as its overall interior depth, so please check the unit’s specs and diagrams to ensure it will accommodate your storage needs.