$4,864.52/Each

Accessories & Options

Condition:

New
Shipping:

Usually Ships in 1-2 Business Days

White Glove Delivery - Available -

What is White Glove service?

Standard common carrier delivery options cover the cost of getting an item to your shipping address but our White Glove delivery service does that and more!

The White Glove agent will call to schedule a delivery appointment within a four hour window, which gives you the flexibility to work around your busy schedule and to prepare the space where your item will be placed. Upon delivery, trained professionals will unload your item from the truck, bring it into the room of choice, unpack the item and remove all packaging debris from the premises.

Please note that White Glove delivery will typically add 5 - 7 business days to your order's transit, and only includes 30 minutes of on-site time. If on-site time beyond 30 minutes is required, you may be responsible for additional fees. While the agents will bring the items into the location of your choice, this service does not include set-up of the items being delivered, such as installation of casters, shelves, or other accessories. Smaller items will not be unpackaged individually; they will be set in place and debris and packaging material will not be removed.

You May Also Need

"You May Also Need" items are guaranteed to work with the item you are viewing, such as lids that will fit a cup or casters that will fit a piece of equipment. If an item is not listed in this section, we do not guarantee that it will work with the product you are viewing and do not recommend that you purchase them for use together.

The Nor-Lake Kold Locker 6' x 6' x 7' 4" indoor walk-in cooler offers versatility and superior storage space all in one easy-to-assemble unit.

Use this walk-in cooler to store large quantities of food at a safe holding temperature. Storing food at the proper temperature can help prevent your ingredients from spoiling too quickly, saving you money on wasted products. With insulated walls and a durable construction, this walk-in cooler is an efficient, long-lasting addition to your establishment!

Floorless Design

This indoor walk-in cooler features a floorless design with vinyl sealers so it can be installed directly on a concrete floor for added structural integrity. This unit includes an electric vaporizer unit to evaporate condensed water inside the walk-in, eliminating the need for a drain line.

Capsule Pak

An innovative, self-contained, top-mounted Capsule Pak cooling unit provides 100% usable interior storage space by utilizing a flush coil design, which keeps all cooling components outside the walk-in cooler. The Capsule Pak installs easily and uses R-404A refrigerant.

Insulation

To maintain consistent temperatures, the panels are also insulated with 4" thick CFC-free HFC polyurethane.

Durable Panels

The panels are made of coated 26 gauge corrosion-resistant embossed galvanized steel for durability and long-lasting use.

External Thermometer

A digital thermometer allows you to verify that the walk-in is maintaining the correct temperature, ranging from 35 to 38 degrees Fahrenheit.

Self-Closing Door

A self-closing door secures easily to the Nor-Lake Kold Locker walk-in with cam lift hinges and has a 26" opening. Plus, a NL9800 deadbolt locking handle with independent padlock secures the door, while an inside safety release protects your staff.

Customer Q&A Ask a Question

How can I determine the size of this product's interior?
The interior of a Nor-Lake cooler can be determined by subtracting 8" from each exterior measurement. Each side panel is 4" thick, and each exterior measurement contains two panels. For Nor-Lake freezers, the panels will be 4"-5" thick, so subtracting 8"-10" from each exterior measurement will give you a good idea of interior size.
Where will the door be located on my walk-in cooler?
The "Walk-In Floor Plans" document on this page has a diagram with all of the possible floor plan options for Nor-Lake walk-in units. This shows the standard and alternate door configurations for each size option.

If you are interested in one of the alternate door configurations, first choose whether you want a left or right door hinge and then check the dropdowns at the top of the page - additional door configurations will be shown there, if any are available, and you can then select the right door configuration code for your application, using the codes in the diagram as a guide. If you don't see an "Optional - Alternate Floor Plans" dropdown, no alternate configurations are available for this particular unit.

Be aware that on units with wall-mounted refrigeration, selecting an alternate door configuration will move the refrigeration unit to the wall opposite the door, for proper airflow.

If you do not choose another floor plan, you will be shipped the standard configuration.
My city or state has special requirements for walk-in refrigeration - what do I need to know before purchasing this item?
Chicago residents: Chicago residents are required to purchase a pressure relief valve with their walk-in cooler. Pressure relief valves are recommended for improved safety. These valves help refrigerant from exceeding dangerous pressures.

Oregon residents: The state of Oregon charges a tagging fee for inbound shipments of this item. You will be contacted regarding this fee after placing your order.

If you have any questions, please contact Special Orders prior to making your purchase.
Does this walk-in cooler come with refrigerant lines?
No, this walk-in cooler does not come with refrigerant lines. They will need to be supplied separately.
Can this item fit through a standard height 80" doorway?
Due to the height of this item, it may not be able to fit through a standard 80" tall doorway when standing upright. Please consider the best means of entry before purchasing, or measure your entryway to ensure that you will be able to bring your order inside if the item cannot be carried on its side.

Nor-Lake Kold Locker 15 Minute Set-Up Demonstration

Putting together your Nor-Lake Kold Locker can be done in about 15 and a half minutes. You will see how easy it is to install yourselves in this step-by-step demonstration video.

Installing your Nor-Lake Kold Locker is fast and easy with just three people and 15 minutes. Here, we show you just how easy it really is. Make sure to keep the included product manual handy for detailed instructions on each step. Take the time to follow the steps explicitly. Start by positioning the foamed walk-in floor panels in the desired location. Secure with the included hex wrench using the technique outlined in the product manual. Next, it's time to install the first corner panel. Notice that the panel is labeled "Top" along with a part number indicating that when the panel is in its proper position, the labeled end will be up. Notice, also, that the section latch access holes on the vertical edge of the panel are always on the interior of the panel. Position the corner panel in the proper location on the walk-in floor and flush the corner panel with the corner of the floor panel in both directions. Lock it securely to the floor panel. Select the next panel as indicated on the floor plan and position it on the floor close enough to the first panel installed so that section latch engagement is possible. Making sure that the two panels are perfectly aligned at the TOP EDGE and that the VERTICAL JOINT of the two panels are perfectly flush, turn the section latches on the vertical edge of the panel until they are completely engaged. Insist that the top edges of the adjoining panels are aligned perfectly and verify with a level. If misalignment is encountered, merely lift the lowest panel edge while locking to achieve alignment and, when all latches are engaged, permit the locked panels to resume their normal position on the walk-in floor. Continue erecting panels according to the part numbers shown on the floor plan, and follow, explicitly, the technique described for panel alignment. Once all of the walls are up, with the exception of the last remaining cornel panel and the front/door panel, it's time to start on the ceiling. Start by placing the condenser atop the proper ceiling panel as outlined in the floor plan. Secure properly before proceeding. Lift the ceiling panel/condenser up into position above the side panels. Next, bring the front/door panel into position and secure. The last remaining corner panel should be placed into position once the front/door panel is positioned, and finally, the last remaining ceiling panel should be positioned. Secure all unsecured panels at this time and seal properly. Then plug the unit into designated wall receptacle and you're done!

Copy and paste the embed code above.

Compare to Other Products

Overall Dimensions:
  • Width: 72 Inches
  • Depth: 72 Inches
  • Height: 88 Inches

This Item Ships via Common Carrier. For more information and tips to help your delivery go smoothly, click here.

Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. If you need your items by a certain date, please contact us prior to placing your order. Expedited shipping availability may vary. We cannot guarantee that this item can be cancelled off of the order or returned once it is placed.

Warranty Info

RESIDENTIAL USERS: The right is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as possible.

Get paid to review this product!

If you've used this product, simply log in and share your text, video, and photo reviews of it. The customers on the left did it, and you can too! Earn up to $16.00 per product.

Login or Register