  • 4" foamed-in-place insulation
  • 3/4 hp 115V top-mounted self-contained refrigeration system
  • Maintains 38 degrees Fahrenheit
  • Smooth aluminum floor helps insulate cooler and protect against condensation
  • 100% usable interior space
  • Ships unassembled for quick and easy installation
Kolpak: Basic Walk-In Installation

Kolpak: Basic Walk-In Installation

Basic walk-in installation. General safety information. First, i'll start with some general safety information. -Installation, maintenance, and servicing are to be performed only by trained and qualified personnel familiar with commercial walk-in products. -Ensure that all fields wiring conforms to the equipment requirements and all applicable local and national codes. -Disconnect all power sources before servicing the unit. -Sheet metal and coil surfaces have sharp edges. - Use appropriate protective gloves to prevent injury. -Use appropriate eye protection during installation and servicing. Receiving Inspection: Carefully inspect for any concealed damage. Report any shortages or damages to the carrier. Not on the bill and file a claim. Panel Identification: Kolpak uses a panel identification system. A similar drawing is shipped with each walk-in and is located in the small parts box. Each panel is labeled to aid in identification of proper placement. Panel item #s are references in the product assembly drawing, showing proper placement for intended installation within the unit. Using the packing list and skid documentation, count the wall panels, corners, ceilings, doors, and floors where applicable. Locate and verify the accessory hardware package. Site Preparation: Part of a successful installation is ensuring that the area is clear of all debris before beginning assembly. If care is not taken to ensure a level base, wall, and ceiling valve, it will not align properly, causing problems in install and operation of door panel, and potentially performance issues due to excessive air leaks. Floor Panel Installation: Review the floor panel layout on the assembly drawing. Panels are labeled with numbers corresponding to those on the assembly drawing. Lay out four panels in correct sequence, according to assembly drawings, and making sure the floor is level. Lock floor panels together, making sure the edges are flush and square. Wall Panel Installation: Review the wall panel and floor section layout on the assembly drawing. Start with the back corner and work around the unit both ways, ending with a front corner. Begin wall panel assembly by cam-locking a back corner panel and one wall panel together. Work around the unit in both directions, ending at opposite corners. Ensure the edges and tops of walls are flush. Screed Installation: Standard screeds are available in both vinyl and metal versions. Walk-ins with screeds have tubes of butyl included in the small parts box. Apply two beads of non-drying butyl on the bottom side of the screws. Secure the screw to the floor using supply fasteners. This video only shows the procedure for installing one screed. Follow the same steps for all remaining screeds. Ceiling Panel Installation: To begin ceiling panel installation, use the assembly drawings for correct panel placement and sequence. Begin with an in-section for a single compartment enclosure, or a T panel for a multi-compartment enclosure. Place ceiling panels in position per the assembly drawings on top of the wall panels . Do not lock ceiling panels to the walls at this time. Then check the panel alignment. Cam lock the ceiling panels together, and after several ceilings panels are in position and locked together check all wall to ceiling drawings for flush fit and proper alignment. Then lock the ceiling panels to the wall panels. Door Section Installation: We will next review the door section installation. It's important to keep the door section locked to prevent the door from opening while handling. This will prevent any safety concerns for those handling it as well as damaging the door. Check the door section with a level to ensure it will closer properly for a tight seal. After all wall panels and door sections are assembled, lock them into the floor screen. Ensure that all remaining wall, floor, and ceiling panel locks are engaged prior to adding plug buttons. Plug Button Installation: Remove protective covering from panels if applied. Check that all cam lock are engaged. Insert plug buttons into the cam lock wrench access holes and firmly tap in place using a rubber mallet. Plug buttons supplied for wall and ceilings are vinyl. Plug buttons supplied for floors are either stainless steel or high-strength plastic.

Copy and paste the embed code above.

Watch this video to see how to install your Kolpak walk-in. step by step!

Kolpak Walk-In Refrigeration

Kolpak Walk-In Refrigeration

Keep your cold foods at proper holding temperatures with Kolpak walk-in refrigerators! Boasting air shields that resist warm air infiltration, Arctic Fox cooling controllers, and energy-efficient LED lights, these refrigerators can reduce energy usage by up to 50%. Plus, they have adjustable hinges, hydraulic actuated door closures, and heavy-duty doors to provide maximum cold holding performance with minimal environmental impact.

Copy and paste the embed code above.

Learn how you can save money and energy with Kolpak walk-in refrigerators!

Specs
Width 116 Inches
Depth 116 Inches
Height 90 1/4 Inches
Door Width 26 Inches
Interior Width 108 Inches
Interior Depth 108 Inches
Door Height 78 Inches
Height (with refrigeration unit) 110 Inches
Refrigeration Unit Height 18 7/8 Inches
Amps 16.8 Amps
Hertz 60 Hertz
Phase 1 Phase
Voltage 115 Volts
Capacity 558 cu. ft.
Compressor Location Top Mounted
Door Style Swing
Door Type Solid
Horsepower 3/4 HP
Made in America Yes
NSF Listed Yes
Refrigerant Type R-448A
Temperature Range 38 Degrees F
Usage Indoor
With Floor Yes

Customer questions about this product

How much clearance is necessary to install this walk-in unit?
For best results, there must be 18" of vertical clearance above the refrigeration unit for top mount units, and 2’ of clearance for side mount units for proper ventilation. Failure to do so may result in overheating.
Where is the door located on this Kolpak walk-in?
On a standard unit, the door will be located on the panel that is listed first in the product dimensions. For example, a 10' x 8' x 7' walk-in will come with the door located on the 10' panel. A 5' x 4' x 6' walk-in will come with the door on the 5' panel. Each panel is made up of smaller sections. The door is fitted onto a 46 1/2" section that can be moved to another panel in the field, as long as it is swapped out with a section of the same 46 1/2" width. In order for the door to be moved, the walk-in must also include a floor.
Can I order an outdoor Walk-in unit?
Kolpak Outdoor Walk-ins require a quote from our special orders team. Please contact us at [email protected]
Can this item fit through a standard height 80" doorway?
Due to the height of this item, it may not be able to fit through a standard 80" tall doorway when standing upright. Please consider the best means of entry before purchasing, or measure your entryway to ensure that you will be able to bring your order inside if the item cannot be carried on its side.
Ask your own question!

Details

The Kolpak QS7-1010-CT indoor walk-in cooler boasts a rugged, high performance design intended for years of trouble-free use. A top-mounted, 3/4 hp refrigeration system fits flush to the interior cavity, giving you 100% usable interior space. Its self-contained design with automatic condensate evaporator doesn't require any plumbing, and it installs easily without the need for a refrigeration technician.

The walk-in's "Posi-Loc" panel fasteners and magnetic gaskets ensure an airtight enclosure for high performance and energy efficiency, and an interior safety release prevents accidental entrapment. This walk-in features a 1/8" smooth aluminum floor that helps insulate the cooler and protect it from condensation forming. This is very important if you do not have a concrete floor at ground level on which to place your cooler.

- Panels made of durable, 26 gauge embossed "Galvalume" steel with 4" polyurethane insulation

- Floor panels can withstand evenly distributed load of 700 lb./sq. ft.

- Adjustable hinges with durable handle; interior safety release prevents accidental entrapment

- 3/4 hp self-contained refrigeration system with R-448A refrigerant maintains 38 degrees Fahrenheit; hot gas condensate evaporator

- 115V

Overall Dimensions:
Width: 9' 8"
Depth: 9' 8"
Height (Without refrigeration unit): 7' 6 1/4"
Height (with refrigeration unit): 9' 2"
Door Width: 26"
Door Height: 78"

Interior Dimensions:
Width: 9'
Depth: 9'
Capacity: 558 cu. ft.

This Item Ships via Common Carrier. For more information and tips to help your delivery go smoothly, click here.

Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. If you need your items by a certain date, please contact us prior to placing your order. Expedited shipping availability may vary. We cannot guarantee that this item can be cancelled off of the order or returned once it is placed.

  • NSF Listed

    NSF Listed

    This item meets the standards imposed by NSF International, which focuses on public safety, health, and the environment.

  • Made in America

    Made in America

    This item was made in the United States of America.

  • UL Listed

    UL Listed

    This item has been tested and meets safety standards imposed by the Underwriters Laboratories (UL).

  • Hardwired

    Hardwired

    This product must be hardwired; it does not plug into a standard wall outlet.

Leave a review of this product!

If you've used this product, log in and leave a review to tell us and other customers what you thought about it. Get paid up to $16 for submitting one of the first text, photo, or video reviews for this item. View your account for details.

Login or Register